Logo
Menu
Contact Us

Metrology Grade

ASTM E77 Standards

ISO/IEC 17025

Laboratory Accreditation

NABL Compliant

India's national body

Precision Tabletop Air Velocity Calibrator

Indeecon's air velocity calibration equipment ensures fume hoods, biosafety cabinets, and cleanroom inlets operate at specified airflow rates—critical for personnel safety and environmental protection. Delivering 0.1–5 m/s measurement accuracy with ±3% repeatability, this tabletop validator supports annual facility compliance audits and troubleshooting of airflow-dependent laboratory equipment. NABL-accredited certificates enable documentation for OSHA, accreditation bodies, and insurance audits.

Range

Controlled Flow

Stability

High Repeatability

Uniformity

High Repeatability

Precision Tabletop Air Velocity Calibrator
NABL Traceable

Key Features

Measurement range: 0.1–5 m/s covering typical fume hood and biosafety cabinet specifications
Digital display with averaging algorithm reduces turbulence-induced noise
Dual-sensor option: thermal anemometer for quick readings, pressure-based for precision audits
NABL-traceable calibration against primary standards for audit compliance
Portable design fits handheld operation while recording 10+ point averages
Data logging stores facility baseline velocity maps for trend analysis
Stainless steel probe resists corrosion from fume hood chemical residue
USB export enables facility compliance reporting and SOP documentation
IP54 sealed construction withstands humid cleanroom and laboratory environments
Integrated alarm flags if measured velocity falls below specification threshold

Compliance

Standards & Certifications

ISO 14644 cleanroom classification and air velocity specifications✓ Compliant
NSF/ANSI 49 biosafety cabinet performance and airflow verification✓ Compliant
ANSI/ASHRAE 110 fume hood containment and face velocity testing✓ Compliant
ISO 17025:2017 portable airflow measurement procedures✓ Compliant

Application Areas

Cleanroom Certification and Compliance

Annual validation of room air changes and velocity at doorways and work surfaces

Biosafety Cabinet Qualification

Verification of critical velocity (0.5 m/s inward) for personnel and product protection

Fume Hood Performance Audits

Routine assessment of hood face velocity to detect ductwork blockages and fan degradation

Laboratory Ventilation Commissioning

Post-installation airflow mapping to confirm HVAC design specifications

Contamination Failure Investigation

Diagnostic airflow testing to determine if product contamination resulted from inadequate ventilation

Pharmaceutical Manufacturing Compliance

Quarterly air velocity monitoring for ISO Class 6–8 cleanroom documentation

Support

Frequently Asked Questions

Related Guides

Continue with the right buying guides

Use the matching guide pages to compare chamber types, evaluation criteria, and implementation paths before finalizing your specification.

Metrology Support

Talk to a Metrologist

Availability

Status

In Stock

Lead Time

2-3 weeks

MOQ

1 Unit

Traceability Chain

NIST/NPL Standard Reference
NABL Accredited Lab
ISO/IEC 17025 Compliance
Certificate Included

1-Year Warranty

Traceability certs included

Related Products

Nearby models and adjacent systems often evaluated during specification and procurement.

-100°C Cryogenic Liquid Calibration Bath for Global Metrology Laboratories

Indeecon Product

Low Temperature Bath

Liquid calibration baths -100°C to +270°C, ±0.005°C stability, 10–15 simultaneous sensors. ISO/IEC 17025 NABL-ready. Cascade refrigeration, refrigerated, and high-temp oil bath models.

View product

Need a calibrated system?

Our metrology team handles NABL-traceable calibration services across India.