Logo
Menu
Contact Us

Metrology Grade

ASTM E77 Standards

ISO/IEC 17025

Laboratory Accreditation

NABL Compliant

India's national body

High-Temp Oil Calibration Bath (up to 270°C)

Indeecon's liquid calibration baths deliver extraordinary precision across four models spanning -100°C to +270°C — with stability as tight as ±0.005°C (L-CRIO-100) and uniformity of ±0.010–0.030°C. Dual-stage cascade refrigeration, high-torque variable-speed stirrers with vertical laminar flow, vacuum-insulated observation ports, and capacity for 10–15 simultaneous sensors make our baths the primary standard for ISO/IEC 17025 NABL calibration laboratories.

Range

+50°C to +270°C

Stability

±0.08°C

Uniformity

±0.1°C

High-Temp Oil Calibration Bath (up to 270°C)
NABL Traceable

Precision Calibration System

Liquid calibration baths are precision thermal vessels filled with temperature-stable liquids (ethanol, methanol, oil, water-glycol blends) used to calibrate and verify temperature sensors. The liquid surrounding sensors provides uniform thermal contact—unlike dry blocks that rely on point contact. This makes liquid baths the primary standard for sensor calibration. Indeecon offers four core models covering -100°C to +270°C with stability down to ±0.005°C, meeting ISO/IEC 17025 and NABL calibration laboratory requirements.

Key Features

Four Model Range: L-CRIO-100 (-100°C to +40°C, ±0.005°C) | L-ULT-80 (-80°C to +60°C, ±0.010°C) | L-REF-30 (-30°C to +100°C, ±0.015°C) | L-OIL-270 (ambient to +270°C, ±0.020°C)
Dual-Stage Cascade Refrigeration: Achieves -100°C deep cryogenic temperatures with exceptional stability — enables calibration of aerospace and research cryogenic sensors
High-Torque Variable-Speed Stirrer: Vertical laminar flow prevents mixing turbulence and thermal gradients — achieves ±0.010–0.030°C uniformity across the calibration volume
10–15 Simultaneous Sensor Capacity: Calibrate RTDs, thermocouples, NTC thermistors, and data loggers in one run — vs. 2–3 sensors typical in dry-block calibrators
Vacuum-Insulated Observation Port: Frost-free viewing windows in cryogenic models allow real-time sensor monitoring without condensation during overnight unattended calibration runs
Intelligent Level Control: Automatic monitoring prevents oil expansion overflows, dry-run pump damage, and unplanned shutdown during thermal cycling
NABL Calibration Ready: ISO/IEC 17025 uncertainty budget pre-certified; RS-232 / Modbus TCP output for LIMS integration
Primary Standard Recognition: Full sensor immersion in temperature-stable liquid provides superior calibration accuracy vs. point-contact dry blocks

Compliance

Standards & Certifications

ISO/IEC 17025 — NABL calibration laboratory readiness; uncertainty budget pre-certified✓ Compliant
ITS-90 — International Temperature Scale of 1990 traceability✓ Compliant
NIST Traceability — Through international calibration networks✓ Compliant
ISO 5725 — Measurement Repeatability and Reproducibility✓ Compliant
IEC 61010-1 — Laboratory Equipment Safety✓ Compliant

Application Areas

Temperature Sensor Calibration

RTDs, thermocouples (all types), NTC thermistors, PT100/PT1000 — simultaneous multi-sensor calibration in a single run

Industrial Thermometer Verification

Process thermometers, digital indicators, and temperature transmitters for QMS compliance

Data Logger & Temperature Indicator Calibration

Traceable calibration for ISO 9001 and IATF 16949 measurement system requirements

Pharmaceutical & Food Safety Testing

Temperature-controlled environment validation; cold chain instrument calibration

Aerospace & Defence Sensor Certification

Cryogenic sensor calibration for avionics and ground support equipment

ISO/IEC 17025 Calibration Laboratories

Primary reference standard bath for NABL-accredited laboratory operations

Support

Frequently Asked Questions

Related Guides

Continue with the right buying guides

Use the matching guide pages to compare chamber types, evaluation criteria, and implementation paths before finalizing your specification.

Metrology Support

Talk to a Metrologist

Availability

Status

In Stock

Lead Time

2-3 weeks

MOQ

1 Unit

Traceability Chain

NIST/NPL Standard Reference
NABL Accredited Lab
ISO/IEC 17025 Compliance
Certificate Included

1-Year Warranty

Traceability certs included

Related Products

Nearby models and adjacent systems often evaluated during specification and procurement.

-100°C Cryogenic Liquid Calibration Bath for Global Metrology Laboratories

Indeecon Product

Low Temperature Bath

Liquid calibration baths -100°C to +270°C, ±0.005°C stability, 10–15 simultaneous sensors. ISO/IEC 17025 NABL-ready. Cascade refrigeration, refrigerated, and high-temp oil bath models.

View product

Need a calibrated system?

Our metrology team handles NABL-traceable calibration services across India.