Logo
Menu
Contact Us
Industrial GradeISO 9001 Certified

Autoclave

Indeecon autoclaves are precision steam sterilisation systems designed for microbiology laboratories, pharmaceutical manufacturing, hospitals, research institutions, and biotech facilities. Our autoclaves deliver reliable, repeatable sterilisation of laboratory media, instruments, glassware, waste, and pharmaceutical products in compliance with EN 13060, EN 285, and cGMP standards. Available in vertical and horizontal orientations with single-door and double-door (pass-through) configurations, Indeecon autoclaves provide flexible solutions for diverse sterilisation workflows.

1-Year Warranty
ISO 9001 Certified
Factory Tested
24/7 Support
Autoclave
Systems Online

Core Engineering Features

Precision Control

Advanced PLC architecture delivering unmatched stability and real-time parameter tracking.

Rugged Construction

Industrial-grade materials engineered for 24/7 continuous operational stress.

Custom Integration

Flexible interfaces for seamless integration with factory automation networks.

Safety Compliance

Multi-tiered fail-safes and interlocks ensuring personnel and facility protection.

Background

What is a Autoclave?

An autoclave is a pressurised steam sterilisation chamber that uses high-temperature saturated steam to kill bacteria, viruses, fungi, and spores on laboratory instruments, media, and materials. Steam penetrates fabrics, wrapped instruments, and porous materials more effectively than dry heat, making autoclaves the standard sterilisation method in microbiology, pharmaceutical, and healthcare settings. Autoclaves operate at temperatures around 121°C (at 15 psi / 1.2 kg/cm²) or 134°C (at 30 psi / 2.1 kg/cm²) for defined time periods. The combination of heat, moisture, and pressure denatures proteins and disrupts cellular structure, ensuring pathogen elimination. Laboratory autoclaves, pharmaceutical autoclaves, and double-door pass-through autoclaves from Indeecon are engineered for reliability, operator safety, and regulatory compliance.

Compliance

Applicable Standards

Standard
Description
Status
EN 13060
— Small steam sterilisers for healthcare facilities
Compliant
EN 285
— Sterilisers for medical devices – Large steam sterilisers
Compliant
ISO 11135
— Validation and routine control of sterilisation by ethylene oxide
Compliant
ASME B
oiler & Pressure Vessel Code (Section VIII, Div. 1) — USA
Compliant
IS 7523
— Indian Standard for pressure cookers and sterilisers
Compliant
cGMP/GMP compliance
cGMP/GMP compliance — Pharmaceutical manufacturing
Compliant
FDA 21 CFR
Part 11 — Electronic records and electronic signatures
Compliant
ISO 14937
— Guidance on selection of sterilisation methods
Compliant
ISO 9001
— Quality management systems
Compliant

Capabilities

What Makes Our Temperature and Humidity Chamber Stand Out

  • Dual Sterilisation Cycles: 121°C pre-vacuum (faster) and 134°C gravity (safer for porous loads)
  • Integrated Steam Generation: High-efficiency electric steam generator with water reserve
  • Precision Control: PLC-based HMI with programmable multi-stage cycles
  • Safety Interlocks: Door safety mechanism preventing opening under pressure
  • Pressure Regulation: Automatic control from 1.2 to 2.1 kg/cm² (15–30 psi)
  • Vacuum System: High-performance water-ring vacuum pump for rapid chamber evacuation
  • ASME Compliance: Pressure-locking doors with spring-loaded safety relief valves
  • SS-316L Construction: Premium stainless steel for corrosion resistance in pharma/biotech
  • Pass-Through Designs: Double-door configurations for BSL-3 labs and cross-contamination control
  • Rapid Drain Cooling: Fast cycle completion with integrated cooling system
  • Multi-Stage Sterilisation Cycles: Gravity displacement, pre-vacuum, and pulse-vacuum options ensure effective sterilisation for all load types — wrapped instruments, porous materials, hollow items, and pharmaceutical products.
  • ASME-Certified Pressure Vessels: Double-walled jackets, locking door mechanisms, and spring-loaded safety relief valves guarantee operator safety and load protection under high-pressure steam.
  • Pass-Through Double-Door Design: Seamless BSL-3 laboratory integration with cross-contamination seals, independent chamber vacuums, and automatic interlocks for biotech manufacturing and research compliance.

INDUSTRIES WE SERVE

Industries That Rely on Our Hot Chamber and Cold Chamber

Microbiology Laboratories

Culture media, petri dishes, glassware, and instruments

Pharmaceutical Manufacturing

Product sterilisation, equipment validation, GMP compliance

Hospitals & Clinics

Surgical instruments, wound care supplies, dental equipment

Biotech & Research

Cell culture media, laboratory glassware, contaminated waste

Food & Beverage

Equipment sterilisation, packaging material processing

Veterinary Clinics

Surgical instruments, laboratory media, animal care supplies

Dental Practices

Handpiece sterilisation, tray instruments, surgical implements

Related Guides

Use the matching technical guides

These pages cover selection criteria, standards, and comparison frameworks relevant to this equipment family.

Frequently Asked Questions

Still have questions? Our engineers are happy to help.

Related Products

Nearby models and adjacent systems often evaluated during specification and procurement.

BOD incubator for biochemical oxygen demand testing and laboratory incubation

Indeecon Product

BOD Incubator

BOD incubator for 5-day biological oxygen demand testing at 20°C ±1°C. Compliant with IS 3025, ISO 5815, and APHA 5210B water quality standards.

View product

Custom Configuration

Need a custom build?

Our engineering team can modify dimensions, controllers, and specs to match your exact protocol.